-29%
,

Schneider Easy9 Residual Current Circuit Breaker – 4P – 63 A – 100 mA – AC type – 400 V


AED128.00 AED180.00

Easy9 Residual Current Circuit Breaker – 4P – 63 A – 100 mA – AC type – 400 V

EZ9R56463
This Easy9 product is a residual current circuit breaker (RCCB). It is a 4P circuit breaker with 63A In rated current, 100mA earth leakage sensitivity and AC type protection class. This product protects against electrical shock by indirect contact and fire hazards. It also has protection against fire hazards due to persistent earth fault current. This product has a positive contact indications with fault tripping indication on the front panel by the position of the handle (0-I engraved). This is dedicated for residential and small commercial buildings market segment. This product is compliant with IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 500A. The (Inc/IΔc) conditional rated short circuit current is 6000A. It has an electrical endurance going up to 2000 cycles and a mechanical endurance going up to 5000 cycles. The Ue operational voltage is 400VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product color is light grey (RAL7035). The dimensions are (W) 72mm x (H) 82mm x (D) 72mm. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.
ActivityHDCFD
Part NumberEZ9R56463
[ui] Rated Insulation Voltage440 V AC
[Uimp] rated impulse withstand voltage4 kV
9 Mm Pitches8
Comb Busbar and Distribution Block Compatibilitytop: YES
Connection Pitch18 mm between phases
Contact Position Indicatoryes
Device Location in Systemoutgoer
Earth-leakage Protection Classtype AC
Earth-leakage Protection Time Delayinstantaneous
Earth-leakage Sensitivity100 mA
Neutral Positionleft
Rated Breaking and Making Capacity500 A
Rated Conditional Short-circuit CurrentEasy9 MCB: 6000 A 63 A
Residual Current Tripping Technologyvoltage independent
Surge Current250 A
Tropicalisation2
Weight354 g
Package1 Length*Width*Height9 cm x 8 cm x 8 cm
Country of ManufacturingIndia
ambient air temperature for operation-5-60 °C
ambient air temperature for storage-40-85 °C
colourgrey (RAL 7035)
connections – terminalstunnel type terminal (top or bottom) 1-35 mm² rigid, tunnel type terminal (top or bottom) 1-25 mm² flexible
control typetoggle
depth72 mm
device short nameEasy9 RCCB
Electrical DurabilityAC: 2000 cycles 400 V AC 50/60 Hz
height82 mm
IP degree of protectionIP20
mechanical durability5000 cycles
mounting modeclip-on
mounting supportDIN rail
network frequency50/60 Hz
network typeAC
Poles Description4P
pollution degree2 conforming to IEC 61008-1
product certificationsCE
product or component typeresidual current circuit breaker (RCCB)
range of productEasy9
relative humidity95-95 % at 55-55 °C
standardsIEC 61008-1
Tightening Torque3.5-3.5 N.m top or bottom
width72 mm
ambient air temperature for operation-5-60 °C
standardsIEC 61008-1
[Ui] rated insulation voltage440 V AC
tightening torque3.5-3.5 N.m top or bottom
Order Now 🔥 ...