Circuit breaker Easypact EZC100H – TMD – 80 A – 3 poles 3d

EasyPact EZC MCCB
EasyPact EZC Molded Case Circuit breakers from 15 to 630A, with fixed settings with just three sizes of circuit breakers, is the simple and universal solution to fit all low-voltage protection needs.

Easy to choose
EasyPact EZC brings you easy solutions with a complete range of auxiliaries, rotary commands, shunt trips, phase barriers, terminal cover, and undervoltage trip.

Easy to install
This affordable and efficient option offers adaptability, effortless installation, and complete security, ensuring both convenience and reliability for users.

Easy to use
A thermal calibration is suitable for MCCB use at 50 °C without derating (up to 250A). Positive contact indication, and a smaller case optimised for tight spaces.
Activity | PPCCB |
---|---|
Part Number | EZC100H3080 |
[ics] Rated Service Breaking Capacity | 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2, 5 kA at 125 V DC conforming to IEC 60947-2, 5 kA at 250 V DC conforming to IEC 60947-2, 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2, 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2, 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2, 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
[ui] Rated Insulation Voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
breaking capacity | 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2, 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2, 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2, 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2, 30 kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2 |
Breaking Capacity Code | H |
Circuit Breaker Name | Easypact EZC100H |
Connection Pitch | 25 mm |
Downside Connection | front |
Earth-leakage Protection | without |
Neutral Protection Setting | without protection |
Protected Poles Description | 3t |
suitability for isolation | yes conforming to IEC 60947-2 |
Trip Unit Name | TM-D |
trip unit rating | 80-80 A at 50 °C |
trip unit technology | thermal-magnetic |
Upside Connection | front |
utilisation category | category A |
Weight | 820.0 g |
Package1 Length*Width*Height | 14.0 cm x 8.5 cm x 9.5 cm |
Country of Manufacturing | Thailand |
ambient air temperature for operation | -25-70 °C |
ambient air temperature for storage | -35-85 °C |
compatibility code | EZC100 |
control type | toggle |
depth | 60 mm |
device application | distribution |
device short name | Easypact EZC100H |
Electrical Durability | category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 |
height | 130 mm |
IK degree of protection | IK07 conforming to IEC 62262 |
IP degree of protection | IP20 conforming to IEC 60529 |
local signalling | positive contact indication |
Market Segment | small commercial |
mechanical durability | 8500 cycles |
mounting mode | fixed |
mounting support | backplate |
network frequency | 50/60 Hz |
network type | DC, AC |
Poles Description | 3P |
pollution degree | 3 conforming to IEC 60664-1, 3 conforming to IEC 947-1 |
Product Name | EasyPact EZC |
product or component type | circuit breaker |
Protection Type | overload protection, short-circuit protection |
range | EasyPact |
range of product | EasyPact |
standards | GB/T 14048.2, JIS C8201-2-2, EN/IEC 60947-2, EN/IEC 60947-1 |
width | 75 mm |
ambient air temperature for operation | -25-70 °C |
standards | GB/T 14048.2, JIS C8201-2-2, EN/IEC 60947-2, EN/IEC 60947-1 |
local signalling | positive contact indication |