-28%
,

Schneider IC60H – earth leakage circuit breaker – 1P + N – C curve – 20 A – 10 mA – 240 V


AED173.00 AED240.00

IC60H – earth leakage circuit breaker – 1P + N – C curve – 20 A – 10 mA – 240 V

A9D10820
This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 20A In rated current and C tripping curve. The earth leakage protection class is A type with a sensitivity of 10mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with AS/NZS 61009.1 and BS EN 61009-1 standards. It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 2. The product color is white (RAL9003). The dimensions are (W) 18mm x (H) 110mm x (D) 77.5mm. The weight is 205g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C.
ActivityHDCFD
Part NumberA9D10820
[ics] Rated Service Breaking Capacity7500 A at 230/240 V AC 50/60 Hz
[icw] Rated Short-time Withstand CurrentIcw: 250 A during 8/20 µs impulse withstand
[Icw] rated short-time withstand currentIcw: 250 A during 8/20 µs impulse withstand
[ui] Rated Insulation Voltage400 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
9 Mm Pitches2
Breaking Capacity10000 A Icn at 230/240 V AC 50/60 Hz
breaking capacity10000 A Icn at 230/240 V AC 50/60 Hz
Breaking Capacity CodeH
Circuit Breaker Applicationdistribution
Comb Busbar and Distribution Block CompatibilityNO
Contact Position Indicatoryes
Curve CodeC
Device Location in Systemoutgoer
Earthing SystemTN
Earth-leakage Protectionintegrated
Earth-leakage Protection Classtype A
Earth-leakage Protection Time Delayinstantaneous
Earth-leakage Sensitivity10 mA
Limitation Class3
Locking Options DescriptionON/OFF locking facilities
Neutral Positionleft
Number of Protected Poles1
Provision for Padlockingpadlockable with padlock Ø 4 mm
Residual Current Tripping Technologyvoltage dependent
suitability for isolationyes
Surge Current250 A
trip unit technologythermal-magnetic
Tropicalisation2
Weight211.0 g
Package1 Length*Width*Height1.8 cm x 9.5 cm x 7.5 cm
Country of ManufacturingThailand
[in] Rated Current20 A at 50 °C
[ue] Rated Operational Voltage230/240 V AC 50/60 Hz
ambient air temperature for operation-15-60 °C
ambient air temperature for storage-40-85 °C
colourwhite
connections – terminalsscrew clamp terminal (top) 1-25 mm² rigid without cable end, screw clamp terminal (top) 1-16 mm² flexible, screw clamp terminal (bottom) 1-16 mm² rigid without cable end, screw clamp terminal (bottom) 1-10 mm² flexible
control typetoggle
depth77.5 mm
device short nameiC60H RCBO
Electrical Durability5000 cycles
height110 mm
IP degree of protectionIP20
local signallingON/OFF indication
mechanical durability20000 cycles
mounting modeclip-on
mounting supportDIN rail
net weight205 g
network frequency50 Hz
network typeAC
Poles Description1P + Ns
Product NameActi9 iC60 RCBO
product or component typeresidual current breaker with overcurrent protection (RCBO)
rangeActi9
relative humidity95-95 % at 55-55 °C
standardsAS/NZS 61009.1, BS EN 61009-1, IEC 61009-1, IEC 61009-2-2
Tightening Torquepower circuit: 3.5-3.5 N.m top, power circuit: 2-2 N.m bottom
width18 mm
Wire Stripping Lengthpower circuit: 13 mm for bottom connection, power circuit: 14 mm for top connection
ambient air temperature for operation-15-60 °C
standardsAS/NZS 61009.1, BS EN 61009-1, IEC 61009-1, IEC 61009-2-2
local signallingON/OFF indication
[Ui] rated insulation voltage400 V AC 50/60 Hz
tightening torquepower circuit: 3.5-3.5 N.m top, power circuit: 2-2 N.m bottom
Order Now 🔥 ...