IC60H – earth leakage circuit breaker – 1P + N – B curve – 32 A – 30 mA – 240 V

A9D34832

This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 32A In rated current and B tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with IEC 61009-1 and IEC 61009-2-2 standards. It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 2. The product color is white (RAL9003). The dimensions are (W) 18mm x (H) 110mm x (D) 77.5mm. The weight is 205g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C.

ActivityHDCFD
Part NumberA9D34832
[ics] Rated Service Breaking Capacity7500 A at 240 V AC 50/60 Hz
[icw] Rated Short-time Withstand CurrentIcw: 250 A during 8/20 µs impulse withstand
[Icw] rated short-time withstand currentIcw: 250 A during 8/20 µs impulse withstand
[ui] Rated Insulation Voltage400 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
9 Mm Pitches2
Breaking Capacity10000 A Icn at 240 V AC 50/60 Hz
breaking capacity10000 A Icn at 240 V AC 50/60 Hz
Breaking Capacity CodeH
Circuit Breaker Applicationdistribution
Comb Busbar and Distribution Block CompatibilityNO
Contact Position Indicatoryes
Curve CodeB
Device Location in Systemoutgoer
Earthing SystemTN
Earth-leakage Protectionintegrated
Earth-leakage Protection Classtype A
Earth-leakage Protection Time Delayinstantaneous
Earth-leakage Sensitivity30 mA
Limitation Class3
Locking Options DescriptionON/OFF locking facilities
Neutral Positionleft
Number of Protected Poles1
Provision for Padlockingpadlockable with padlock Ø 4 mm
Residual Current Tripping Technologyvoltage dependent
suitability for isolationyes
trip unit technologythermal-magnetic
Tropicalisation2
Weight211.0 g
Package1 Length*Width*Height2.7 cm x 14.3 cm x 10.3 cm
Country of ManufacturingThailand
[in] Rated Current32 A at 50 °C
[ue] Rated Operational Voltage240 V AC 50/60 Hz
ambient air temperature for operation-15-60 °C
ambient air temperature for storage-40-85 °C
colourwhite
connections – terminalsscrew clamp terminal (top) 1-25 mm² rigid without cable end, screw clamp terminal (top) 1-16 mm² flexible, screw clamp terminal (bottom) 1-16 mm² rigid without cable end, screw clamp terminal (bottom) 1-10 mm² flexible
control typetoggle
depth77.5 mm
device short nameiC60H RCBO
Electrical Durability5000 cycles
height110 mm
IP degree of protectionIP20
local signallingON/OFF indication
mechanical durability20000 cycles
mounting modeclip-on
mounting supportDIN rail
net weight205 g
network frequency50 Hz
network typeAC
Poles Description1P + N
Product NameActi9 iC60 RCBO
product or component typeresidual current breaker with overcurrent protection (RCBO)
rangeActi9
range of productActi9
relative humidity95-95 % at 55-55 °C
standardsIEC 61009-1, IEC 61009-2-2
Tightening Torquepower circuit: 3.5-3.5 N.m top, power circuit: 2-2 N.m bottom
width18 mm
Wire Stripping Lengthpower circuit: 13 mm for bottom connection, power circuit: 14 mm for top connection
ambient air temperature for operation-15-60 °C
standardsIEC 61009-1, IEC 61009-2-2
local signallingON/OFF indication
[Ui] rated insulation voltage400 V AC 50/60 Hz
tightening torquepower circuit: 3.5-3.5 N.m top, power circuit: 2-2 N.m bottom