Schneider IC60L – miniature circuit breaker – 2P – 20A – B curve


IC60L – miniature circuit breaker – 2P – 20A – B curve

A9F93220
This Acti9 iC60L is a low voltage miniature circuit breaker (MCB). It has 2P with 2 protected poles, rated current 20A and B tripping curve. The rated short circuit breaking capacity goes up to 50kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 15000A at 400VAC conforming to EN/IEC 60898-1 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker is for protection against short circuit and overload current in all applications. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit. Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. It is DIN rail mountable. Its width is 4 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 78.5mm. The weight is 0.25kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C.
ActivityHDCFD
Part NumberA9F93220
[ics] Rated Service Breaking Capacity12.5 kA 50 % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz, 10 kA 50 % conforming to EN 60947-2 – 440 V AC 50/60 Hz, 12.5 kA 50 % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz, 10 kA 50 % conforming to IEC 60947-2 – 440 V AC 50/60 Hz, 25 kA 50 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz, 25 kA 50 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz, 35 kA 50 % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz, 35 kA 50 % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz, 7500 A 50 % conforming to EN 60898-1 – 400 V AC 50/60 Hz, 7500 A 50 % conforming to IEC 60898-1 – 400 V AC 50/60 Hz, 20 kA 100 % conforming to EN 60947-2 – 72…125 V DC, 20 kA 100 % conforming to IEC 60947-2 – 72…125 V DC
[ui] Rated Insulation Voltage500 V AC 50/60 Hz conforming to EN 60947-2, 500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN 60947-2, 6 kV conforming to IEC 60947-2
9 Mm Pitches4
Breaking Capacity70 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2, 50 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2, 15000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1, 70 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2, 20 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2, 20 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2, 25 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
breaking capacity15000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1, 50 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2, 70 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2, 70 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2, 20 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2, 20 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2, 25 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking Capacity CodeL
Comb Busbar and Distribution Block Compatibilitytop or bottom: YES
Connection Pitch18 mm between phases
Contact Position Indicatoryes
Curve CodeB
Earth-leakage Protectionseparate block
Limitation Class3 conforming to EN 60898-1, 3 conforming to IEC 60898-1
Magnetic Tripping Limit4 x In +/- 20 %
Number of Protected Poles2
overvoltage categoryIV
suitability for isolationyes conforming to EN 60898-1, yes conforming to EN 60947-2, yes conforming to IEC 60898-1, yes conforming to IEC 60947-2
trip unit technologythermal-magnetic
Tropicalisation2 conforming to IEC 60068-1
utilisation categorycategory A conforming to EN 60947-2, category A conforming to IEC 60947-2
Weight227.0 g
Package1 Length*Width*Height9.4 cm x 3.5 cm x 7.5 cm
Country of ManufacturingBulgaria
[in] Rated Current20 A
[ue] Rated Operational Voltage440 V AC 50/60 Hz, 220…240 V AC 50/60 Hz, 400 V AC 50/60 Hz, 380…415 V AC 50/60 Hz, 12…133 V AC 50/60 Hz, 72…125 V DC
ambient air temperature for operation-35-70 °C
ambient air temperature for storage-40-85 °C
colourwhite
compatibility codeiC60
connections – terminalssingle terminal (top or bottom) 1-25 mm² rigid, single terminal (top or bottom) 1-16 mm² flexible
control typetoggle
depth78.5 mm
device applicationdistribution
device short nameiC60L
Electrical Durability10000 cycles
height85 mm
IP degree of protectionIP20 conforming to IEC 60529, IP20 conforming to EN 60529
local signallingtrip indicator
Market Segmentsmall commercial, residential
mechanical durability20000 cycles
mounting modefixed
mounting supportDIN rail
net weight0.25 kg
network frequency50/60 Hz
network typeDC, AC
operating altitude0…2000 m
Poles Description2P
pollution degree3 conforming to EN 60947-2, 3 conforming to IEC 60947-2
Product NameActi9 iC60
product or component typeminiature circuit-breaker
rangeActi9
range of productiC60
relative humidity95-95 % at 55-55 °C
standardsEN 60898-1, EN 60947-2, IEC 60947-2, IEC 60898-1
Tightening Torque2-2 N.m top or bottom
width36 mm
Wire Stripping Length14 mm for top or bottom connection
ambient air temperature for operation-35-70 °C
standardsEN 60898-1, EN 60947-2, IEC 60947-2, IEC 60898-1
local signallingtrip indicator
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to EN 60947-2, 500 V AC 50/60 Hz conforming to IEC 60947-2
tightening torque2-2 N.m top or bottom
Order Now 🔥 ...